Toilet Retrofit / Water Fixture Upgrade

97 Unit Building - circa 1960 Year of Construction. Savings =  $70 / day or $25,760 over one (1) Year.
Total Project Cost:  Parts +  Materials + Labour =   $23,500. Payback:  11 mos

  • 55 out of 97 Toilets were replaced with 3.0L units

  • Showerheads upgraded to 1.5 GPM

  • Kitchen Aerators upgraded to 1.5 GPM

  • Bath Vanity Aerators upgraded to 1.0 GPM

Leak Rate from 18.6% to 0.0%

Day

 

Leak

Total Volume

Leak as % Total

Thurs

11,282

60,599

18.62%

Fri

7,497

48,615

15.42%

Sat

5,979

46,791

12.78%

Sun

5,878

58,749

10.01%

Mon

5,878

47,386

12.40%

Tues

2,008

43,580

0.46%

Wed (*)

0

16,466

0

Before: Consumption per unit / day  = 0.62 m3 / unit / day. After:  Consumption per unit / day  =  0.45 m3 / unit / day

As a result of:

  1. replacing toilets that were > 3.0 L

  2. replacing shower heads and;

  3. installing aerators on kitchen sinks and bath vanities

The leak rate as a percentage of total consumption was reduced from 18% to 0%.  In addition to eliminating the leaks, the per unit usage on a daily basis has dropped as a result of the more efficient toilets being rolled out. The building inventory of toilets are now all 3.0L with a mix of ProFlo (new ones installed) and Hennesy Henchcliffe (legacy 3.0 L already installed).

3.0L Toilet replacements throughout.
Bath Vanity Aerators upgraded to 1.0 GPM

Summary Daily Usage with Leak Rate Reduction 

  • Leak rate dropped from 18% to 0%

  • Daily volume dropped from 60k / day to approx 40k / day

60 Day Snapshot : Oct 7th Completion Date

  • Drop in daily consumption

  • Elimination of leak rate by address toilets, showerheads and aerators

  • Before / During and After   Installation was Oct 4th - Oct 7th, 2021

Pre Retrofit Weekly Pattern

Post Retrofit Weekly Pattern - Notable drop in off peak usage 

24 Hour Usage Pre Retrofit

  • 17.7% Leak rate

  • Avg Flow  41.9 L / min

24 Hour Usage Post Retrofit 

  • Drop in overall usage.  Average Flow 25.6L / min

  • Significant periods in off peak with no water usage.  Zero (0) % leak rate